Door Control Electronics
|
| DorControl - Automation without complication |
Easy to install controllers for industrial roller-shutter, roll-up
and sectional door systems.
Functions: |
- OPEN / CLOSE functions by impulse operations and
press-and-hold push-button operations with or without safety
devices fitted. HALF OPEN / HALF CLOSE by double
pressing of impulse button.
- STOP - Emergency STOP button on front panel
of enclosure. Interruption of any safety element during
operation will also stop a moving operator.
- AUTOCLOSE - Selectable autoclose feature which
can only be initiated when safety element has been fitted.
Time intervals of 5 - 180 seconds, selectable.
- TRAVEL LIMITS - Open, Closed and Half Open
- TRAFFIC LIGHT CONTROL - Optional plug-in relay
board for remote indication of door status. Indications
include OPEN, CLOSED and DOOR MOVING (flashing)
- COUNTER FACILITY - Provision is made for an electronic
counter to be connected to the DorControl to read the number
of door cycles.
- INDICATIONS - Enclosure Housing - LED indicating
power ON.
- PCB LED's indicate door position, control signals,
power and status inputs.
- REMOTE CONTROL - Optional plug-in 433MHz RF receiver.
- MOTOR RUN TIME - Selectable time settings to limit
motor run time.
|
 |
|
Mail sales@sensablesensors.co.za
for specific technical information and support.
|
| MiniControl - Automation with Protection |
The MiniControl Controller is a compact industrial door automation
controller which incorporates a unique current sensing circuit to
protect the 230 Volt Single Phase or 230 Volt / 400 Volt Three Phase
electrical motor.
Functions:
- OPEN/CLOSE functions by impulse operation or press-and-hold
operation.
- STOP- Emergency STOP button on front panel.
- CURRENT SENSING - Selectable overload protection
with manual or automatic reset.
- LIMIT SWITCHES - Controls motors with mechanical
limits.
- AUTOCLOSE - Fixed duration autoclose selection.
- SAFETY - Facility for connection of photocells,
safety edges or inductive loop vehicle detectors.
- CONTROL - Facility for connection of any external
control elements.
- REMOTE CONTROL - Optional plug-in 422MHz RF Receiver.
- STATUS INDICATION - Power, Inputs, Photocell and
Open/Closed.
- MOTION RELAY - For control of external warning
lights.
|
 |
|
An infared optosensor safety device, which provides the ultimate protection
against injury and damage caused by moving objects.
Applications:
- Industrial Doors
- Industrial Automation
- Domestic Garage Doors
|
- Traffic Barriers
- Sliding Gates
|
|
Features:
- Permanent signal on deformation of the rubber profile
- Functional reliability because the system is not affected
by moisture or temperature
- Response sensitivity is automatic in accordance with the
door barrier width.
- Terminal assignment is simple due to plug in connectors
for optosensors and screw terminal for connection to operators
/ controllers.
|
 |
Mail sales@sensablesensors.co.za
for specific technical information and support.
|